*230 Jahn Lab – Leem research group*
The IEC CL10 performs complete basic centrifuge available. It’s compact, the space-saving design delivers reliable separations quickly and safely. The IEC CL 10 is programmable, and allows to choose the right level of acceleration or deceleration for preference, and ensures speeds and times are accurate. |
|
Balance 1 & 2
: Explorer pro EP114C, Zero TR603D This is on a gram scale and two key navigation. Protective in-use cover and security bracket included in the second instrument. * Upper: Max- 110g, Bottom: Max1– 110g, Max2– 610g |
|
Rotavapor is used to concentrate on some required material by using the same conditions. By using some rotavapors they can concentrate several samples at one time with the same condition.
* Temperature is 20 ⁰C- 180 ⁰C |
![]() : BuchI 461 Water bath & BuchI RE 121
|
* Serum/plasma: 13400rpm for 120s
Urine: 8000rpm for 45s |
|
This is controlled by the microprocessor and it has a solid inner and outer door with a glass window. 1410 has a 0.6 cubic foot capacity with 9″ width x 12″ depth x 9″ height. Features separate vacuum and gas ports with separate manual valves. |
|
This instrument is used in environmental field applications. SB70P can store up to 10 parameters and includes built calibration feature include with password protection allowing for multiple users to be added to the pH meter controller. |
|
|
*232 Jahn Lab – Leem research group *
Viscotek T50 Differential Viscometer with Wyatt Technology OPTILAB DSP Interferometric Refractometer, DAWN DSP laser photometer. |
|
This instrument used for the identification of all raw materials in one hierarchical manner. It also can be used to do the statistical evaluation, internal validation and use of the identification of a compound that you are testing. |
|
This instrument is designed for high-performance liquid chromatography (HPLC) applications. It provides sensitivity, stability, and reproducibility for the analysis of components with limiting UV or no UV absorption. The detector functions with solvents with refractive indices between 1.00 and 1.75. The measurement range of the instrument is 7 × 10–9 to 5 × 10–4 refractive index units full scale. |
|
Ultrasonic cleaning is a process that uses ultrasound (usually from 20–40 kHz) to agitate a fluid. The ultrasound can be used with just water but the use of a solvent appropriate for the item to be cleaned. |
|
Designed for use with 2 to 4.6 mm I.D. columns in routine HPLC applications, the pump has a programmable flow-rate range of 0.00 to 10.00 mL/min in 0.01 mL increments. It features an integrated, high-pressure binary pump with on-board pulse dampening and efficient mixing. |
|
|
*234 Jahn Lab – Leem research group*
Three high-temperature box furnaces This instrument has the ability to operate temperature from 50 ⁰C – 1125 ⁰C. Temperature value and control parameters are shown on two red 7-segment displays. Two LED’s indicate when heater power is being applied or when an over-temperature error condition is encountered. |
![]() |
PC1 is a highly sensitive, compact, computer-controlled. The design optimizes the light path so that the sample compartment receives the maximum possible excitation light. The instrument has the ability to measure fluorophores with very low quantum yields. |
|
|
|
|
|
It will provide a broadband light source with specific spectral emissions in the ultraviolet (UV) or near-infrared (NIR) regions. It includes a Hg(Xe) lamp (200W or 500W) selected for the requirements, research lamp housing, xenon lamp power supply. |
|
|
|
|
|
An FID typically uses a Hydrogen/Air flame into which the sample is passed to oxidize organic molecules and produces electrically charged particles (ions). The ions are collected and produce an electrical signal which is then measured. |
![]() : Thermo GC Focus Series |
Additional instruments and information will be uploaded.